Mostrar el registro sencillo del documento

dc.creatorRodríguez Aparicio, Edith Elianna
dc.creatorCarrizosa Gonzalez, Jorge Armando
dc.creatorRodriguez-Lima, David Rene
dc.date.accessioned2022-12-19T20:30:01Z
dc.date.available2022-12-19T20:30:01Z
dc.date.created2022-11-19
dc.identifier.issn2524-8987spa
dc.identifier.urihttp://repositorio.mederi.com.co/handle/123456789/723
dc.descriptionBackground Increases in the diameter of the optic nerve sheath (ONSD) on ultrasound are associated with high intracranial pressure (hICP). The normal value varies with altitude and the population studied. The objective of this study is to describe the normal values of the ONSD in a healthy adult population of the city of Bogotá, Colombia, at 2640 meters above sea level (masl). Patients and methods A prospective observational study was conducted on a total of 247 healthy individuals recruited from May 2021 to May 2022 who were subjected to the color, low power, optic disk, safety, elevated frequency, dual (CLOSED) protocol for measuring the bilateral ONSD adjusted to the eyeball transverse diameter (ETD). Results A total of 230 individuals were analyzed; the average ONSD of the right eye (RE) was 0.449 cm (range 0.288–0.7) and that of the left eye (LE) was 0.454 cm (range 0.285–0.698); the correlation between RE and LE was 0.93 (p < 0.005), and the correlation of the ONSD/ETD ratios for the RE and LE was lower (r2 = 0.79, p < 0.005). A total of 10.8% of the studied population had values greater than 0.55 cm. Conclusions The median ONSD and ONSD/ETD ratio in the city of Bogotá are similar to those described in other populations; however, approximately 10.8% of the healthy population may present higher values, which would limit the use of ONSD on its own for clinical decision-making, only repeated measurements with significant changes in the ONSD and ONSD/ETD or asymmetries between the measurements of both eyes linked to clinical findings would allow the diagnosis of hICP.spa
dc.format.mimetypeapplication/pdfspa
dc.relation.urihttps://doi.org/10.1186/s13089-022-00295-1spa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.titleOptic nerve sheath diameter at high altitude: standardized measures in healthy volunteersspa
dc.subject.keywordUltrasoundspa
dc.subject.keywordOptic nerve sheath diameterspa
dc.subject.keywordEyeball transverse diameterspa
dc.subject.keywordAltitudespa
dc.subject.keywordIntracranial pressurespa
dc.subject.keywordNormal valuespa
dc.subject.keywordNormal populationspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionacceptedVersionspa


Archivos en el documento

ArchivosTamañoFormatoVer

No hay archivos asociados a este documento.

Este documento aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del documento

Atribución-NoComercial-SinDerivadas 2.5 ColombiaExcepto si se señala otra cosa, la licencia del documento se describe como Atribución-NoComercial-SinDerivadas 2.5 Colombia