Mostrar el registro sencillo del documento

dc.creatorAragón DazaI, María Laura
dc.creatorRodríguez Velásquez, Javier Oswaldo
dc.creatorPrieto Bohórquez, Signed Esperanza
dc.creatorCorrea Herrera, Sandra Catalina
dc.creatorRodríguez, Henry Oliveros
dc.creatorSoracipa Muñoz, María Yolanda
dc.creatorBermúdez Narváez, Luis Eduardo
dc.creatorPardo Oviedo Juan Mauricio
dc.creatorRubio Martínez, Juan Carlos
dc.creatorOrtiz Salamanca, Liliana Astrid
dc.date.accessioned2020-01-02T19:01:51Z
dc.date.available2020-01-02T19:01:51Z
dc.date.created2019-12
dc.identifier.issn2227-1899spa
dc.identifier.urihttp://repositorio.mederi.com.co/handle/123456789/462
dc.descriptionIntroducción: La evolución de un sistema dinámico se pueden caracterizar a partir de la construcción de atractores caóticos. Objetivo: desarrollar una metodología de evaluación de la saturación venosa de oxígeno para pacientes en Unidad de Cuidados Intensivos, fundamentada en los sistemas dinámicos. Metodología: se seleccionaron 10 pacientes con diferentes patologías de la Unidad de Cuidados Intensivos Postquirúrgicos, y registró la saturación venosa de oxígeno durante su tiempo de estancia. Con base en estos valores se construyeron atractores caóticos en el mapa de retardo y se evaluaron de los valores mínimos y máximos ocupados por el atractor. Resultados: se halló que la saturación venosa de oxígeno tiene un comportamiento caótico; los valores máximos y mínimos de los atractores en el mapa de retardo variaron entre 22,10 mmHg y 93,70 mmHg. Conclusiones: se plantea una nueva metodología capaza de caracterizar el comportamiento de esta variable monitorizada para la evaluación del paciente crítico.spa
dc.description.abstractIntroduction: The evolution of a dynamic system can be characterized from the construction of chaotic attractors. Objective: to develop a methodology for the evaluation of venous oxygen saturation for patients in the Intensive Care Unit, based on dynamic systems. Methodology: 10 patients with different pathologies of the Post-Surgical Intensive Care Unit were selected, and recorded the venous oxygen saturation during their stay. Based on these values, chaotic attractors were built on the delay map and evaluated for the minimum and maximum values occupied by the attractor. Results: it was found that venous oxygen saturation has a chaotic behavior; the maximum and minimum values of the attractors in the delay map varied between 22.10 mmHg and 93.70 mmHg. Conclusions: a new methodology is proposed capable of characterizing the behavior of this monitored variable for the evaluation of the critical patient.spa
dc.format.mimetypeapplication/pdfspa
dc.relation.urihttp://www.revinformatica.sld.cu/index.php/rcim/article/view/330/pdf_100spa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.subjectfractalesspa
dc.subjectdinámica no linealspa
dc.subjectmodelos teóricosspa
dc.titleEvaluación de la Saturación Venosa de Oxígeno desde la teoría de los sistemas dinámicosspa
dc.title.alternativeEvaluación de SvO2 desde los sistemas dinámicosspa
dc.subject.keywordfractalsspa
dc.subject.keywordnon-linear dynamicsspa
dc.subject.keywordtheoretical modelsspa
dc.rights.accessRightsopenAccessspa
dc.type.hasVersionacceptedVersionspa


Archivos en el documento

ArchivosTamañoFormatoVer

No hay archivos asociados a este documento.

Este documento aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del documento

Atribución-NoComercial-SinDerivadas 2.5 ColombiaExcepto si se señala otra cosa, la licencia del documento se describe como Atribución-NoComercial-SinDerivadas 2.5 Colombia